Skip to content

Liquid silicone rubber (LSR) injection molding

Cold-runner LSR molding for wearable components, microfluidic valves and industrial seals. Share STEP or STP files and service conditions to review the gate, parting line and critical tolerances.

Horizontal molding press with a robotic arm lifting translucent elastomer parts
±0.05–0.10 mmSelected critical dimensions · ISO 3302-1 M1
5–80Shore A hardness range
50–250 tfLSR press clamping force
ISO Class 7 / 8Cleanroom molding by project

Three LSR molding routes for precision elastomer parts

Choose the molding route based on sealing geometry, the substrate interface and how any inserts must be located in the tool.

Cold-runner LSR molding

Review valve gates, cavity venting and shutoffs to control flash around sealing edges and small valve features.

LSR overmolding on rigid substrates

Match the silicone grade to the substrate and its cure-temperature limits. Decide whether to use a primer, a self-bonding grade or mechanical retention.

LSR molding around metal or ceramic inserts

Define the insert datum, exposed areas and shutoffs first. Specify pull-out, torque or sealing checks to match the insert’s function.

LSR, HCR and TPE/TPU process comparison

Selection factorLSRHCRTPE / TPU
Molding and cureMetered two-part injection and heat curingSolid silicone charge pressed and cured in the toolThermoplastic melt injected and cooled
Dimensions and flashReview the sealing edge, parting line and required tolerance class.Check the parting line and allowance for trimming.Account for shrinkage and warpage of the exact grade.
Thin walls and detailCheck gate location and venting at thin features.Check charge placement and compression flow.Check melt flow, draft and ejection.
Operating environmentValidate the selected grade against temperature and media.Review the solid silicone compound and cure system.Confirm grade-specific heat, oil and abrasion resistance.
Seal recoveryCheck post-cure conditions and compression-set data.Compare compression-set results for the cured compound.Evaluate compression and creep over the actual duty cycle.
Cleanliness and documentationAgree on the cleanroom class, batch traceability and grade documents.Review preform handling, trimming and cleaning requirements.Review compound-specific declarations and handling conditions.

Compare actual grades and test conditions when you specify a tolerance, service temperature or compression set.

Typical LSR parts and applications

Use these examples to identify which dimensions, functional requirements and records belong on your drawing.

Skin-contact cushions and wearable pads

Agree on skin contact duration, surface finish, hardness and any biocompatibility documentation required for the chosen grade and finished part.

Micro check valves and diaphragms

Specify opening pressure, leakage and cyclic life. Mark the slit, thin walls and sealing features that need verification.

Rectangular gasket frames and protective bellows

Define gland dimensions, compression and demolding direction. When IP68 is a target, validate it on the assembled product under the specified test conditions.

Four engineering checks before tooling

Review venting, hardness and post-cure, sealing geometry, and grade-specific documentation before locking the mold design.

Keep the parting line clear of critical sealing surfaces

Uncured LSR can enter fine parting-line gaps. Review shutoff fit, vacuum venting and gate placement together, then agree on a flash limit for each critical area.

On the 2D drawing, mark seal lips, flash-sensitive edges and areas where a gate mark is acceptable.

LSR capabilities and inspection criteria

Use these figures for an initial review. The approved drawing, process route and quote set the requirements for the part.

Liquid silicone rubber molding
ItemCapability and conditions
Available seriesElastosil LR 3003 / 3040 / 3070 / 3071 · Silastic LC-3330 / LC-3350 / QP1 · Silopren LSR 2000 / 2600 · Shin-Etsu KE-2000
Hardness range and toleranceShore A 5–80 · Shore A 20–70 · ±3 Shore A
Colors and post-curePantone / RAL · ΔE ≤ 1.0–1.5 · 150–200 °C × 2–4 h
Food and medical documentation by grade21 CFR 177.2600 · LFGB · USP Class VI · ISO 10993-5 / -10 / -11 · DMF
Cleanroom molding arrangementsISO Class 7 / Class 8

Shore A 20–70 is the usual range. Agree color, cure schedule, cleanroom requirements and report coverage for the selected grade and part.

Press and part envelope
ItemCapability and conditions
LSR presses50–250 tf · 15–450 g · 300 × 300 × 120 mm

Rows show clamp force, shot mass and part envelope. Material, tool fit and usable shot size are evaluated together.

Molded part tolerances and inspection
ItemCapability and conditions
Selected LSR features±0.05–0.10 mm · ISO 3302-1 M1
Conditioning and measurement23 ±2 °C · 50 ±5% RH · 24 h · VMM / CMM

Ranges apply to selected parts and features. Agree size, resin, shrinkage and cosmetic master before FAI. DIN 16742 / ISO 20457 and ISO 3302-1 references follow the drawing and specified edition.

Non-contact inspection and traceable delivery

Agree on the inspection method and packaging conditions before production release, especially for soft parts that deform under contact pressure.

Optical measurement and lot testing

Use optical measurement for selected contours and apertures. Define Shore A hardness, tear strength or leak testing according to the part’s function.

Compartment trays and clean packaging

Separate soft parts to protect seal lips from contact and deformation. Confirm the cleanliness level, packing method and batch label for the order.

  1. 01

    DFM review

    Agree on gating, visible surfaces and which dimensions control assembly or function.

  2. 02

    Cold-runner tooling

    Set the cavity layout, shutoffs and venting based on the approved design.

  3. 03

    T1 trial and first-article inspection

    Submit trial samples and the agreed inspection records for approval before batch production.

  4. 04

    Batch release and traceability

    Tie incoming resin lot IDs to production records and deliver the agreed documentation and packaging.

Build your LSR engineering brief and request a quote

Choose any known requirements and attach the brief to your inquiry. You can also upload drawings and leave the engineering choices open.

LSR specification configurator

Target hardness (Shore A)
Molding route
Preferred material series
Compliance and post-processing

Submit drawings and project inquiry

Drawings & reference files

STEP/STP, PDF, JPG or PNG. Up to 3 files; 10 MB each, 20 MB total.

No files selected

    No drawing yet? Describe the part and application below.

    LSR injection molding FAQs

    How do I choose between LSR, HCR and TPE?

    Start with the geometry, operating temperature, media and required recovery. Compare candidate grades under the same test conditions and select the process that meets both the drawing and batch requirements.

    When should an LSR part be post-cured?

    Review post-curing when the grade or application requires control of residual volatiles or final properties. Specify the required inspection state and testing with the engineering team before tool approval.

    What should I check on a substrate for LSR overmolding?

    Check the exact substrate grade against the cure temperature and clamping loads. Use molded samples to validate adhesion and verify that the substrate stays within the required dimensions.

    What should I send for an LSR engineering review?

    Send STEP/STP geometry and a 2D drawing marking critical tolerances and flash limits. Include target Shore A, trial and annual quantities, contact media, service temperature and required documents.

    KEEPWIN · LANGUAGE

    Choose your language

    Select the language you prefer for your visit.

    You can change your language anytime in the menu.