Corrosion protection and wear resistance
Review electroless nickel for machined features, zinc for carbon steel and hard chrome for selected wear surfaces. On deep bores, specify the minimum thickness and the point to check.
Specify a finish for corrosion protection, electrical contact or appearance. We review the substrate and finish together with critical dimensions, masking and measurement, for supplied parts or a coordinated machining and plating order.
Start with the working surface, base alloy and finish required by the drawing. Define the layers separately where they have different functions.
Review electroless nickel for machined features, zinc for carbon steel and hard chrome for selected wear surfaces. On deep bores, specify the minimum thickness and the point to check.
Specify gold or silver for the required contact or RF surface, or tin for the specified soldering interface. Control the underplate, contact zone, finish and test method for the application.
Review bright nickel–chromium or black nickel against a physical sample. Specify gloss, visible faces and allowed rack marks. For prolonged skin contact, confirm the applicable nickel-release requirements for the finished article.
The figures apply to the named substrate and layer stack. Other combinations, coating class, hardness and corrosion tests are confirmed against the drawing.
| Coating | Thickness or review scope | Specification reference | Substrate and acceptance | Contact and CAD files |
|---|---|---|---|---|
| Electroless nickel (ENP) | 10–25 μm | ASTM B733 | Carbon or alloy steel reference. Confirm phosphorus class, heat treatment and significant surfaces. | |
| Zinc electroplating | 8–12 μm | ASTM B633 | Carbon-steel parts. Specify the passivation or seal, appearance and corrosion acceptance. | |
| Tin electroplating | 5–10 μm | ASTM B545 | Copper or copper-alloy parts. Agree finish and solderability requirements. | |
| Gold electroplating | 0.5–2.0 μmNickel underplate 3–5 μm | ASTM B488 | Copper-based contacts. Confirm the contact area, gold type and nickel underplate separately. | |
| Silver electroplating | 3–8 μmNickel underplate 3–5 μm | ASTM B700 | Copper-based conductive surfaces. Agree the silver zone, underplate and any tarnish protection. | |
| Electroplated nickel | Agree on drawing | ASTM B689 | Confirm the purpose, layer stack and substrate-specific activation. Brightness follows the approved finish. | |
| Engineering hard chrome | Agree on drawing | ASTM B177/B177M | Selected wear surfaces and fits. Plan grinding allowance and the final dimensional check with the coating. | |
| Decorative nickel / trivalent chrome | Agree on drawing | ASTM B456 | Confirm the base and undercoat, trivalent chemistry where requested, gloss and reference sample. | |
| Black nickel / gunmetal | Agree on drawing | Approved physical sample | Confirm shade, gloss, underlying layers, any seal and wear acceptance. |
Mark the plating and masking boundaries on the drawing. If a smooth bore is coated on both sides, its diameter decreases by about twice the coating thickness. Review thread geometry separately and verify it with agreed gauges after plating.
Review XRF when the layers and measuring locations are suitable. Specify thickness by layer, measurement points and sampling. Agree the adhesion method, specimen and salt spray duration and acceptance criteria when needed.
Dimensional inspection illustration
Separate plated contacts and cosmetic parts so they do not rub together. For silver, agree compatible anti-tarnish materials. Specify ESD packaging only where the product requires it, and link the agreed reports to the lot.
Define which dimensions apply before and after plating. For bearing seats and threads, agree masking, pre-plate allowance or finish machining and plan the final measurement.
Yes. Identify the intended finish, key interfaces and final acceptance in one drawing package. For supplied parts, tell us the exact alloy, prior surface treatment and present condition.
XRF depends on layer composition, accessible geometry and calibration. Agree significant points and an alternate method, such as a section measurement when needed.
Provide the use conditions, physical finish sample and applicable market requirements. For prolonged skin contact, arrange any nickel-release testing on the finished article.
Provide substrate grade, quantity, layer thickness, masked areas and final fit. Name the standard and revision, and include any inspection, sample or compliance requirements.
Example for copper contacts: specify the base alloy, nickel underplate and gold layer separately.